Abstract

Background

Hemodialysis patients are at risk of acquiring healthcare-related infections due to using non-sterile water to prepare hemodialysis fluid. Therefore, microbiological control and monitoring of used water are of crucial importance.

Materials and methods

In this work, we identified bacterial populations occupying a hemodialysis water distribution system for almost a 6-month period in Ahvaz city, southwest of Iran. A total of 18 samples from three points were collected. We found high colony counts of bacteria on R2A agar. 31 bacteria with different morphological and biochemical characteristics were identified by molecular-genetic methods based on 16 S rRNA gene sequencing. Endotoxin concentrations were measured, using Endosafe® Rapid LAL Single-Test Vials.

Results

A diverse bacterial community was identified, containing predominantly Gram-negative bacilli. The most frequently isolated genus was Sphingomonas. Five species including M. fortuitum, M. lentiflavum, M.szulgai, M. barrassiae, and M. gordonae was identified .Despite the presence of Gram-negative bacteria the endotoxin analysis of all samples revealed that their endotoxin values were below the detection limit.

Conclusion

The members of Sphingomonas genus along with Bosea and mycobacteria could be regarded as pioneers in surface colonization and biofilm creation. These bacteria with others like Pelomonas, Bradyrhizobium, staphylococcus, and Microbacterium may represent a potential health risk to patients under hemodialysis treatment.

Peer Review reports

Introduction

End-stage kidney disease (ESKD) is a significant public health problem worldwide. Patients with ESKD suffer from a systemic impairment, and the direct effect of uremic conditions and its metabolic outcomes makes them more susceptible to infection. These disorders include abnormalities of neutrophils, lymphocytes B, T and monocytes, the processing of defective antigens, production of antibodies and cellular immune responses, thus increasing the incidence of microbial infections [1]. ESKD is becoming more common throughout the world. The prevalence of ESKD is 242 cases per one million population and it increases by about 8% annually [2]. During 2000–2019, the number of incident ESKD cases increased 41.8%, from 92,660 to 131,422 in the United States [3].

In Iran, considering the growing number of patients living with ESKD in the past 10 years, annually; an average number of 4,000 cases are estimated continuously to be added to ESKD patients’ pool [4, 5].

Hemodialysis (HD) is a renal replacement therapy for ESKD patients. This technique is based on the use of an artificial kidney (dialyzer) that removes nitrogenous waste products from the blood by diffusion and unwanted water by ultrafiltration [6]. During an average week of hemodialysis, a patient can be exposed to 300–600 L of water, providing multiple opportunities for potential patient exposure to waterborne pathogens [7].

Therefore, hemodialysis water treatment requires softening, carbon filtration, reverse osmosis, and deionization before it can be used [7]. Bacteriostatic agent, chlorine, which is added for disinfection of drinking water, gets removed from dialysis water during water treatments. This makes the water susceptible to bacterial proliferation [8]. Therefore, bacterial contamination of the dialysis water and dialysate may cause biofilm (glycocalyces) formation and release of endotoxins in the Hemodialysis system [7]. Endotoxins (ET) are heat-stable lipopolysaccharides (LPS) and the major cell wall components of Gram-negative bacteria. The molecular mass of LPS ranges between 2,000 and 20,000 Da. LPS can be transferred through membranes with large pore sizes by back filtration/diffusion from the dialysis fluid to the blood compartment [9]. HD water quality control is a public health problem on a worldwide scale, with quality standards being recommended in all countries. The European Renal Association (ERS) recommends values of ≤ 100 colony-forming units (CFU)/ml of viable bacteria and ≤ 0.5 IU/ml ET as safety criteria for hemodialysis fluid [10]. The Japanese Society for Dialysis Therapy (JSDT) recommends a count of viable bacterial cells of Less than 100 CFU/mL, and a maximum of 0.05 EU / mL of ET [11].

According to the American Association for the Advancement of Medical Instrumentation (AAMI), the maximum count limit for heterotrophic bacteria is 100 CFU/mL, and 0.25 EU/mL for endotoxin [12]. The reason behind these strict restrictions is that bacteremia and chronic inflammation may contribute to morbidity and mortality [7].

However, despite these strict standards, waterborne outbreaks in the hemodialysis setting continue to occur. Nevertheless, periodic microbial control conducted at hemodialysis center’s do not include analysis of nontuberculous mycobacteria (NTM), and there are few published reports on the isolation and identification of these organisms. Currently, there is a growing interest in NTM disease as a result of the association of NTM infections with immune-suppression [13].

The aim of this study was to investigate the bacteriological quality of the hemodialysis water used at a public hemodialysis center in Ahvaz city, southwestern Iran by isolating and identifying the Gram-negative and Gram-positive bacteria and NTM.

Materials and methods

Water samples collection

This cross-sectional study was conducted for 6 months, from April 2019 to September 2019, at a public hemodialysis center in Ahvaz, Southwest Iran. A total of 18 samples were collected. Three points were selected for sampling: municipality water reservoir stock (point1), water softener (point2), and Outlet of RO equipment (point3) (Fig. 1). Two samples (500 ml) were collected separately for bacterial and Mycobacterium cultures at each time point. In addition, the samples for ET analysis (10 mL of water) were collected aseptically in pyrogen-free glass bottles with a screw cap.

Fig. 1
figure 1

Schematic of water treatment system and points of sampling

Endotoxin detection

Endotoxin concentrations were measured, using Endosafe® Rapid LAL Single-Test Vials (STV) containing gel-clot Limulus amebocyte lysate (LAL) (Charles River Laboratories, USA). Aseptically added directly 0.2 mL of sample into LAL assay tube; gently mixed. Immediately placed the reaction tubes in a 37 °C water bath for 60 min. Recorded results by inverting the tube 180 degrees for firming gel. A positive product control was used by the kit.

Bacterial culture and strain isolation

Briefly, 0.1 ml of each sample was pipetted and inoculated on Reasoner’s 2 A agar plates (R2A; Merck, Germany) and incubated at 22 °C for 7 days. The number of colonies obtained was multiplied by 10 to obtain the CFU/ml. For NTM Isolation, 500 ml of each sample was filtered through a 0.45-µm pore size membrane filter (Millipore, Bedford, U.S.A) and decontaminated using 0.005% cetylpyridinium chloride (CPC) (30 min in room temperature). The sediment obtained after centrifugation was suspended in 2 mL of phosphate-buffered saline (PBS) and inoculated into two Löwenstein -Jensen (LJ) media (HiMedia, India), and incubated at 37 and 25 °C for 2 months [14]. The cultures were monitored weekly to observe colony growth, morphology, and pigmentation. Grown colonies were stained by the Ziehl-Neelsen technique to highlight the presence of acid-fast bacilli. Phenotypical and biochemical tests accompanied by 16 S rRNA sequence analysis techniques were used to identify the acid-fast bacilli.

Bacterial isolates identification and characterization

Each of the isolates was observed for the colony morphological characters such as color, size, shape, transparency, texture, and margin. Homogeneous-looking colonies were collected and propagated. Microscopic features were determined through Gram staining.

Biochemical characterization

The pure cultures isolates were differentiated by various biochemical characteristics such as catalase and oxidase reaction, citrate utilization, urea hydrolysis, indole and H2S production. Based on the morphological examination and biochemical assays, all obtained pure cultures were classified into the genera and identified to the species according to 16 S rRNA Sequencing.

Molecular identification using 16 S rRNA sequencing

The genomic DNA of isolated bacteria was extracted using QIAamp DNA Mini Kit (Qiagen, Germany) according to the manufacturer’s instructions. Furthermore, the 16SrRNA gene amplification and sequencing were carried out via the following universal primers: fD1 (5´-AGA GTT TGA TCC TGG CTC AG-3´) and rD1 (5´-AAG GAG GTG ATC CAG CC-3´) [15]. Each reaction was run with a 50 ml mix using I-Taq Maxime PCR Premix (iNtRON Biotechnology, Korea). PCR was conducted via the conditions described previously [16]. PCR-amplified products of about 1450 bp were obtained from the 16 S rDNA of all the strains. In all stages of DNA extraction and PCR, sterile distilled water was used as a negative control and Escherichia coli strain K-12 (ATCC 10,798) was used as a positive control. The amplicons were sequenced in both directions by an external service (bioneer Inc, South Korea). All sequences were edited and assembled using DNA Sequence Assembler v4 (2013). Partial 16 S rRNA sequences were compared with the sequences available in the NCBI database (http://www.ncbi.nlm.nih.gov) using BLASTN [17, 18]. Evolutionary analysis was carried out in MEGA6 based on the Maximum Likelihood algorithm with the Kimura-2-parameter model [19, 20] and 1000-bootstrap replication. Isolates were assigned to a species when their 16 S rRNA gene sequences were at least 99% identical to a reference isolate clearly.

Nucleotide sequence accession numbers

The GenBank accession numbers of investigated bacterial isolates determined in this work are: OP824847, OP824849, OP824855, OP824877, OP824878, OP829813-OP829817, and OP847377-OP847396.

Results

We found high colony counts of bacteria on R2A agar. All 18 samples presented positive cultures and the number of culturable bacteria increased from the municipal reservoir (point 1) to the dialysis fluid outlets (point 3). The mean colony count in each point was respectively 2.2 × 102, 7.1 × 102, and 10.5 × 102 CFU/mL. Gram staining results showed that Gram-negative bacilli were dominant in all samples (61.3%), but faecal coliforms were not detected. Based on the phenotypic characteristics, they were classified into groups and one isolate from each group was randomly selected for or 16 S rRNA gene sequencing. Out of 18 samples from all locations at the HD centre, 31 isolates (19 Gram-negative, 7 Gram-positive and 5 NTM) were studied. At least one Gram-negative isolate could not be identified even by the 16 S rRNA gene sequencing analysis. According to the 16 S rRNA gene sequencing analysis (Fig. 2), the most frequently isolated genus was Sphingomonas (in terms of number and variety).

Fig. 2
figure 2

Phylogenetic tree of 16s rRNA sequences. The evolutionary distances were computed using the Kimura 2-parameter method with 1000 bootstrap replication. Phylogenetic analyses were conducted in MEGA6. Closed circles () indicate the out-group

Unlike Gram-negative bacteria, the number and variety of Gram-positive bacteria were low and limited to three genera. A total of 11 NTM suspected isolates from all three points were included in the study. These isolates were identified on the basis of growth conditions, biochemical characters, and the sequence analysis of the 16s rRNA. Ten confirmed sequences belonged to five species including M. fortuitum, M. lentiflavum, M.szulgai, M. barrassiae, and M. gordonae. The infectious potential of isolates in humans is listed in Tables 1, 2 and 3. Nevertheless, it is important to mention that the phylogeny of the 16 S rRNA gene is not accurate for species identification in this genus.

Table 1 Some characteristics of all Gram-negative isolated bacteria and their related human infections
Table 2 All Gram-positive isolated bacteria from dialysis system and their related human infections
Table 3 Nontuberculous mycobacteria (NTM) isolated from dialysis system and their related human infections

Despite the presence of Gram-negative bacteria, the endotoxin analysis of all samples revealed that their endotoxin values were below the detection limit.

Discussion

Hemodialysis is an alternative therapy for patients with chronic renal failure, increasing the quality and quantity of life of these patients. The quality of the hemodialysis water is of paramount importance in ensuring patient safety [11, 52].

In the present study, we assessed the quality of the main and treated water used at a public hemodialysis center in Ahvaz, Iran. The dialysis department at the public hospital in Ahvaz is a major regional center handling a high volume of cases. It is one of the largest facilities in the southwest, serving around 400 patients monthly across three daily shifts. The patient load comprises emergency admissions, local chronic cases, and patients from other cities, and those with advanced kidney disease, diabetes, cancer, including both men and women. There are reports of the presence of nontuberculous mycobacteria (NTM) strains in major parts of the water supplies at hospitals in Ahvaz, which could potentially serve as a source for nosocomial infections [53]. Originally, the authors discovered through their literature review that water-source infections were a known issue. However, they found that no previous study had specifically focused on isolating and investigating these infections across different environments. This gap in research, especially in specialized settings like the one they were examining, motivated the authors to conduct their own study to fill this knowledge gap and shed light on the topic.

Investigating the microbiological quality of water requires attention to the type of culture medium, incubation temperature and incubation time. Furthermore, hospital waters are highly oligotrophic habitats and bacteria have adapted their metabolic characteristics to this environment [54], so in order to isolate these bacteria, we use Reasoner’s 2 A agar, a low-nutrient culture medium, an incubation temperature of around 22 °C and an incubation period of 7 days for detecting viable bacterial counts in hemodialysis water as a standard method approved by the United States and the European Pharmacopoeia [55, 56].

The findings of this study demonstrate a diverse microbial community of bacteria in HD water. Gram-negative bacteria are the major contaminants of water in hemodialysis units as reported elsewhere [54, 57] as seen in the results (Table 1).

Although the microbiological quality of municipal water that flows to the hemodialysis center met drinking water regulations [7], removing the bacteriostatic agent chlorine from the dialysis water makes it susceptible to bacterial proliferation [58] therefore in line with other studies [58, 59], we observed an increase in culturable bacteria from the municipal reservoir to the dialysis fluid outlets.

The most abundant and diverse isolates belonged to the family Sphingomonadaceae (Sphingomonas and Sphingobium). Members of this family are strictly aerobic with a characteristic yellow pigmentation. The capacity of sphingomonads to adapt to the human-engineered environments is remarkable. For instance, they are able to survive in chlorinated water and produce biofilms. Due to the fact that sphingomonads are opportunistic pathogens [21, 26, 28, 60,61,62], their ubiquity and abundance are potentially hazardous, mainly in hospital waters.

Another bacteria that were identified in abundance was Bosea species. Members of the genus Bosea are Mn (II)-oxidizing bacteria [63]. Methylobacteria was another Mn (II)-oxidizing bacteria isolated in this study. Evidence shows that Methylobacteria survive and even grow in sterile autoclaved water [64]. Biogenic Mn oxides have strong oxidative characteristics and rapidly oxidize other metals, such as chromium and arsenic, which affects their speciation, solubility, and toxicity. In addition to their strong redox activity, Mn oxides degrade refractory organic compounds, which may affect the growth of microorganisms in water distribution systems [65]. On the other hand, studies showed that compared with healthy controls, HD patients have significantly higher blood levels of some heavy metals like lead, arsenic and cadmium [66, 67]. It is possible that there may be a relationship between the high levels of heavy metals in the body of hemodialysis patients and the presence of Mn-oxidizing bacteria in the dialysis water. Furthermore, Bosea and Methylobacterium species were previously documented as opportunistic pathogens in humans. Bosea massiliensis isolated in this research have been reported from intensive care unit (ICU) patients [22]. Other Bosea species cause eye infection [68], central venous catheter infection and bacteremia [22]. Methylobacterium species have been involved in immunocompromised patients and are frequently isolated from blood, liquor cerebrospinalis, bone marrow, synovia, and ascitic and peritoneal fluids. Also, methylobacterium pseudo-outbreaks after endoscopic and bronchoscopy procedures have been related to contaminated tap water [69, 70].

This study has provided five NTM species which are potentially pathogenic (Table 3). The most prevalent species was M. fortuitum followed by M. gordonae. This was in agreement with the findings of the study conducted by Roshdi Maleki et al. in the northwest of Iran [71].

The findings show that hemodialysis water can be considered a reservoir for NTM. Cell surface hydrophobicity is a major determinant of the survival and proliferation of NTM in water distribution systems. Also, NTM can survive within Free-living amoeba (FLA), like Acanthamoeba [72]. The presence of amoebae in dialysis water has been proven [73]. FLA in water are hosts to many bacterial species living in such an environment [74] like Mycobacterium, Variovorax, Bosea, and Acidovorax [75] that were found in this study. Since many of the pathogenic and potentially pathogenic bacteria which interact with FLA are water-borne there is a clear risk for hemodialysis patients.

Most of the bacteria isolated in this work have already been isolated from raw and treated waters [54, 76]. In addition to this, the presence of most of them is supposed to be due to the existence of biofilm in the water distribution system. Bacteria such as Acidovorax sp., Pelomonas sp [54]. , Variovorax sp. [77], Sphingomonads sp [78]. , Bosea sp. [79], Bradyrhizobium sp. [80], Caulobacter sp. [81]. Aquabacterium sp [82]. , Microbacterium sp [83]. staphylococcus sp [84]. Kocuria sp [85]. , and mycobacteria sp [86]. , have been previously isolated from biofilms in various environments. Biofilms on reverse osmosis membranes in hemodialysis facilities harbor diverse bacterial communities, including potentially pathogenic and antibiotic-resistant strains, posing health risks to patients [52].

In this study we have isolated some slime-forming bacteria, like Sphingomonas [87] and Bosea [88] produce extracellular complex carbohydrates and play an essential role in biofilm establishment. NTM also have high cell surface hydrophobicity, which facilitates the formation of biofilms [89]. These three types of bacteria were identified as being the most common genera in the present study and could be considered pioneers in colonizing surfaces and creating biofilm communities. Remarkably, sphingomonas and mycobacterium were found in all three sampling points, an indication of their predominant role of them in the bacterial community.

The microbiological quality of water in dialysis units is critically dependent upon the presence of biofilm in the distribution network. Stagnation and high water temperature in the dialysis machine cause microbiological growth and biofilm formation in the dialysis system pipes. An endotoxin-free dialysate does not exclude the risks and hazards of bacteria and an endotoxin discharge from the biofilms, which may have developed on the fluid pathway tubing, may act as a reservoir for continuous contamination.

According to the current guidelines characterization of bacterial communities in hemodialysis water is usually limited to the total viable count.

However, based on the information provided, there are several potential impacts and ways this survey could help the hospital:

  1. 1.

    Identifying Potential Pathogens: The survey identified opportunistic bacteria like Sphingomonas, Bosea, Methylobacterium, and NTM species. This knowledge allows the hospital to target these organisms in their surveillance efforts, potentially leading to earlier detection and improved patient care.

  2. 2.

    Tailoring Disinfection Protocols: Understanding the specific bacterial communities present allows for more targeted disinfection strategies. The hospital can choose methods that effectively address the identified organisms within their water system.

  3. 3.

    Mitigating Biofilm Risks: The presence of Sphingomonas highlights the importance of biofilm management. The hospital can implement protocols to disrupt and remove biofilms, preventing them from becoming a persistent source of contamination.

  4. 4.

    Identifying Environmental Reservoirs: Finding NTM and other opportunistic pathogens suggests the water system as a potential reservoir for hospital-acquired infections. This awareness can guide targeted interventions to minimize risks for vulnerable patients.

  5. 5.

    Benchmarking Future Monitoring: This survey serves as a baseline for future monitoring. The hospital can track changes in bacterial populations over time and assess the effectiveness of any implemented interventions.

  6. 6.

    Informing Policy Updates: The recommendation to revisit evaluation methods aligns with potential policy updates by public health authorities. This survey’s findings can contribute to improving overall water quality standards in hemodialysis settings.

Data availability

The datasets generated and analyzed during the current study are available in the NCBI GenBank repository under accession numbers; OP824847, OP824849, OP824855, OP824877, OP824878, OP829813-OP829817, and OP847377-OP847396.

References

  1. Montanari LB, Sartori FG, Cardoso MJO, Varo SD, Pires RH, Leite CQF et al. Microbiological contamination of a hemodialysis center water distribution system. Revista do Instituto de Medicina Tropical de São Paulo. 2009;51:37–43.

  2. USRDS. USRDS Annual data report: epidemiology of kidney disease in the United States. 2018.

  3. Burrows NR, Koyama A, Pavkov ME. Reported cases of end-stage kidney disease - United States, 2000–2019. MMWR Morbidity Mortal Wkly Rep. 2022;71(11):412–5. https://doi.org/10.15585/mmwr.mm7111a3.

    Article  Google Scholar 

  4. Mousavi SSB, Soleimani A, Mousavi MB. Epidemiology of end-stage renal disease in Iran: a review article. Saudi J Kidney Dis Transplantation. 2014;25(3):697.

    Article  Google Scholar 

  5. Nafar M, Aghighi M, Dalili N, Alipour Abedi B. Perspective of 20 years Hemodialysis Registry in Iran, on the Road to Progress. Iran J Kidney Dis. 2020;14(2):95–101.

    PubMed  Google Scholar 

  6. Raimundo R, Preciado L, Belchior R, Almeida CM. Water quality and adverse health effects on the hemodialysis patients: an overview. Therapeutic Apheresis Dialysis. 2023;27(6):1053–63.

    Article  PubMed  Google Scholar 

  7. Coulliette AD, Arduino MJ. Hemodialysis and water quality. Semin Dial. 2013;26(4):427–38. https://doi.org/10.1111/sdi.12113.

    Article  PubMed  PubMed Central  Google Scholar 

  8. Liu X, Wang J, Liu T, Kong W, He X, Jin Y, et al. Effects of assimilable organic carbon and free chlorine on bacterial growth in drinking water. PLoS ONE. 2015;10(6):e0128825.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Abbass AA, El-Koraie AF, Hazzah WA, Omran EA, Mahgoub MA. Microbiological monitoring of ultrapure dialysis fluid in a hemodialysis center in Alexandria. Egypt Alexandria J Med. 2018;54(4):523–7.

    Article  Google Scholar 

  10. European Pharmacopoeia. (Ph. Eur.). European directorate for the quality of medicines & healthcare. https://www.edqm.eu/en/european-pharmacopoeia. Accessed 12 Mar, 2023. In.; 2019.

  11. Mineshima M, Kawanishi H, Ase T, Kawasaki T, Tomo T, Nakamoto H, et al. 2016 update Japanese Society for Dialysis Therapy Standard of fluids for hemodialysis and related therapies. Ren Replace Therapy. 2018;4(1):15. https://doi.org/10.1186/s41100-018-0155-x.

    Article  Google Scholar 

  12. ISO—ISO 23500-Preparation. and quality management of fluids for haemodialysis and related therapies—Part 3: Water for haemodialysis and related therapies. https://www.iso.org/standard/67612.html. Accessed 12 Mar, 2023. In.; 2019.

  13. Winthrop KL, Roy EE. Mycobacteria and immunosuppression. Handbook of systemic Autoimmune diseases. Elsevier; 2020. pp. 83–107.

  14. Peters M, Müller C, Rüsch-Gerdes S, Seidel C, Göbel U, Pohle H, et al. Isolation of atypical mycobacteria from tap water in hospitals and homes: is this a possible source of disseminated MAC infection in AIDS patients? J Infect. 1995;31(1):39–44.

    Article  CAS  PubMed  Google Scholar 

  15. Golshan M, Jorfi S, Haghighifard NJ, Takdastan A, Ghafari S, Rostami S, et al. Development of salt-tolerant microbial consortium during the treatment of saline bisphenol A-containing wastewater: removal mechanisms and microbial characterization. J Water Process Eng. 2019;32:100949.

    Article  Google Scholar 

  16. Jorfi S, Ghafari S, Ramavandi B, Soltani RDC, Ahmadi M. Biodegradation of high saline petrochemical wastewater by novel isolated halotolerant bacterial strains using integrated powder activated carbon/activated sludge bioreactor. Environ Prog Sustain Energy. 2019;38(4):13088.

    Article  Google Scholar 

  17. Morgulis A, Coulouris G, Raytselis Y, Madden TL, Agarwala R, Schäffer AA. Database indexing for production MegaBLAST searches. Bioinf (Oxford England). 2008;24(16):1757–64. https://doi.org/10.1093/bioinformatics/btn322.

    Article  CAS  Google Scholar 

  18. Seol D, Lim JS, Sung S, Lee YH, Jeong M, Cho S, et al. Microbial identification using rRNA operon region: database and tool for metataxonomics with long-read sequence. Microbiol Spectr. 2022;10(2):e02017–21.

    Article  PubMed  PubMed Central  Google Scholar 

  19. Tamura K, Peterson D, Peterson N, Stecher G, Nei M, Kumar S. MEGA5: molecular evolutionary genetics analysis using maximum likelihood, evolutionary distance, and maximum parsimony methods. Mol Biol Evol. 2011;28(10):2731–9. https://doi.org/10.1093/molbev/msr121.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  20. Tamura K, Stecher G, Peterson D, Filipski A, Kumar S. MEGA6: Molecular Evolutionary Genetics Analysis version 6.0. Mol Biol Evol. 2013;30(12):2725–9. https://doi.org/10.1093/molbev/mst197.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  21. Guner Ozenen G, Sahbudak Bal Z, Bilen NM, Yildirim Arslan S, Aydemir S, Kurugol Z et al. The First Report of Sphingomonas yanoikuyae as a Human Pathogen in a child with a central nervous system infection. The Pediatric infectious disease journal. 2021;40(12):e524; https://doi.org/10.1097/inf.0000000000003301.

  22. Skipper C, Ferrieri P, Cavert W. Bacteremia and central line infection caused by Bosea thiooxidans. IDCases. 2020;19:e00676.

    Article  PubMed  Google Scholar 

  23. Gyarmati P, Kjellander C, Aust C, Kalin M, Öhrmalm L, Giske CG. Bacterial Landscape of Bloodstream infections in neutropenic patients via high throughput sequencing. PLoS ONE. 2015;10(8):e0135756. https://doi.org/10.1371/journal.pone.0135756.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  24. Xu J, Moore JE, Millar BC, Alexander HD, McClurg R, Morris TC, et al. Improved laboratory diagnosis of bacterial and fungal infections in patients with hematological malignancies using PCR and ribosomal RNA sequence analysis. Leuk Lymphoma. 2004;45(8):1637–41. https://doi.org/10.1080/10428190410001667695.

    Article  CAS  PubMed  Google Scholar 

  25. Orsborne C, Hardy A, Isalska B, Williams SG, Muldoon EG. Acidovorax oryzae catheter-associated bloodstream infection. J Clin Microbiol. 2014;52(12):4421–4.

    Article  PubMed  PubMed Central  Google Scholar 

  26. Chen MF, Chang CH, Chiang-Ni C, Hsieh PH, Shih HN, Ueng SWN, et al. Rapid analysis of bacterial composition in prosthetic joint infection by 16S rRNA metagenomic sequencing. Bone Joint Res. 2019;8(8):367–77. https://doi.org/10.1302/2046-3758.88.bjr-2019-0003.r2.

    Article  PubMed  PubMed Central  Google Scholar 

  27. Ojha MM, Ansari MAA, Janardhanan R, Kumar V. Uncommon Pathogen: Achromobacter xylosoxidans infection following total knee arthroplasty. J Orthop Case Rep. 2024;14(5):28.

    Article  PubMed  PubMed Central  Google Scholar 

  28. Crespo Quirós J, Tornero Molina P, Martín-Rabadán P, Cuevas Bravo C. Baeza Ochoa de Ocáriz ML. Sphingomonas ginsenosidimutans and Bacillus cereus: New agents associated with hypersensitivity pneumonitis. The journal of allergy and clinical immunology In practice. 2021;9(2):1035-6.e1; https://doi.org/10.1016/j.jaip.2020.10.017.

  29. Zhang W, Chen Y, Shi Q, Hou B, Yang Q. Identification of bacteria associated with periapical abscesses of primary teeth by sequence analysis of 16S rDNA clone libraries. Microb Pathog. 2020;141:103954.

    Article  CAS  PubMed  Google Scholar 

  30. Flores-Carrero A, Paniz-Mondolfi A, Araque M. Nosocomial bloodstream infection caused by Pseudomonas alcaligenes in a preterm neonate from Mérida, Venezuela. J Clin Neonatology. 2016;5(2):131.

    Article  Google Scholar 

  31. Aggarwal M, Vijan V, Vupputuri A, Nandakumar S, Mathew N. A rare case of fatal endocarditis and sepsis caused by Pseudomonas aeruginosa in a patient with chronic renal failure. J Clin Diagn Research: JCDR. 2016;10(7):OD12.

    Google Scholar 

  32. Vadehra D, Montesano P, Singvi A. Staphylococcus Epidermidis and Hemodialysis: A Deadly Duo Causing Native Valve Endocarditis. In: C53 critical care case reports: you give me (more) fever - infection and sepsis. p. A5308-A.

  33. Bernier A-M, Bernard K. Draft genome sequences of Microbacterium hominis LCDC-84-0209T isolated from a human lung aspirate and Microbacterium laevaniformans LCDC 91 – 0039 isolated from a human blood culture. Genome Announcements. 2016;4(5):e00989–16.

    Article  PubMed  PubMed Central  Google Scholar 

  34. Gneiding K, Frodl R, Funke G. Identities of Microbacterium spp. encountered in human clinical specimens. J Clin Microbiol. 2008;46(11):3646–52.

    Article  PubMed  PubMed Central  Google Scholar 

  35. do Carmo Ferreira N, Schuenck RP, dos Santos KR, de Freire Bastos Mdo C, Giambiagi-deMarval M. Diversity of plasmids and transmission of high-level mupirocin mupA resistance gene in Staphylococcus haemolyticus. FEMS immunology and medical microbiology. 2011;61(2):147–52; https://doi.org/10.1111/j.1574-695X.2010.00756.x.

  36. Hosseinkhani F, Emaneini M, van Leeuwen W. High-quality genome sequence of the highly resistant bacterium Staphylococcus haemolyticus, isolated from a neonatal bloodstream infection. Genome Announcements. 2017;5(29). https://doi.org/10.1128/genomea. 00683 – 17.

  37. Yu D, Chen Y, Pan Y, Li H, McCormac MA, Tang YW. Case report: Staphylococcus gallinarum bacteremia in a patient with chronic hepatitis B virus infection. Ann Clin Lab Sci. 2008;38(4):401–4.

    CAS  PubMed  Google Scholar 

  38. Chang H-Y, Tsai W-C, Lee T-F, Sheng W-H. Mycobacterium gordonae infection in immunocompromised and immunocompetent hosts: a series of seven cases and literature review. J Formos Med Assoc. 2021;120(1):524–32.

    Article  PubMed  Google Scholar 

  39. Sethi S, Arora S, Gupta V, Kumar S. Cutaneous Mycobacterium fortuitum infection: successfully treated with Amikacin and Ofloxacin Combination. Indian J Dermatology. 2014;59(4):383–4. https://doi.org/10.4103/0019-5154.135491.

    Article  Google Scholar 

  40. Morgans HA, Mallett KF, Sebestyen Vansickle JF, Warady BA. Mycobacterium fortuitum infection of a hemodialysis catheter in a pediatric patient. Hemodialysis international International Symposium on Home Hemodialysis. 2019;23(3):E93-e6; https://doi.org/10.1111/hdi.12731.

  41. Jiang SH, Roberts DM, Dawson AH, Jardine M. Mycobacterium fortuitum as a cause of peritoneal dialysis-associated peritonitis: case report and review of the literature. BMC Nephrol. 2012;13:35. https://doi.org/10.1186/1471-2369-13-35.

    Article  PubMed  PubMed Central  Google Scholar 

  42. Adékambi T, Raoult D, Drancourt M. Mycobacterium barrassiae sp. nov., a Mycobacterium moriokaense group species associated with chronic pneumonia. J Clin Microbiol. 2006;44(10):3493–8. https://doi.org/10.1128/jcm.00724-06.

    Article  PubMed  PubMed Central  Google Scholar 

  43. Kim JJ, Lee J, Jeong SY. Mycobacterium szulgai pulmonary infection: case report of an uncommon pathogen in Korea. Korean J Radiol. 2014;15(5):651–4.

    Article  PubMed  PubMed Central  Google Scholar 

  44. Lotfi H, Sankian M, Meshkat Z, Soltani AK, Aryan E. Mycobacterium szulgai pulmonary infection in a vitamin D–deficient patient: a case report. Clin Case Rep. 2021;9(3):1146.

    Article  PubMed  PubMed Central  Google Scholar 

  45. Neves S, Pos E, Horta A, Vasconcelos AL. Mycobacterium szulgai Pulmonary infection in an immunocompromised patient. Cureus. 2023;15(12).

  46. Kempisty A, Augustynowicz-Kopec E, Opoka L, Szturmowicz M. Mycobacterium szulgai lung disease or breast Cancer Relapse—Case Report. Antibiotics. 2020;9(8):482.

    Article  PubMed  PubMed Central  Google Scholar 

  47. Yagi K, Morimoto K, Ishii M, Namkoong H, Okamori S, Asakura T, et al. Clinical characteristics of pulmonary Mycobacterium lentiflavum disease in adult patients. Int J Infect Dis. 2018;67:65–9.

    Article  PubMed  Google Scholar 

  48. Phelippeau M, Dubus J-C, Reynaud-Gaubert M, Gomez C, Stremler le Bel N, Bedotto M, et al. Prevalence of Mycobacterium lentiflavum in cystic fibrosis patients, France. BMC Pulm Med. 2015;15(1):1–5.

    Article  Google Scholar 

  49. Martinez-Poles J, Saldaña‐Díaz AI, Esteban J, Lara‐Almunia M, Vizarreta Figueroa AT, Martín‐Gil L, et al. Meningoencephalitis due to Mycobacterium lentiflavum in an immunocompromised patient: Case report. Eur J Neurol. 2023;30(4):1152–4.

    Article  PubMed  Google Scholar 

  50. Chida K, Yamanaka Y, Sato A, Ito S, Takasaka N, Ishikawa T, et al. Solitary pulmonary nodule caused by pulmonary Mycobacterium lentiflavum infection. Respiratory Med Case Rep. 2021;34:101510.

    Google Scholar 

  51. Mello RBd, Moreira DN, Pereira ACG, Lustosa NR. Cutaneous infection by Mycobacterium lentiflavum after subcutaneous injection of lipolytic formula. An Bras Dermatol. 2020;95:511–3.

    Article  Google Scholar 

  52. Cuevas J-P, Moraga R, Sánchez-Alonzo K, Valenzuela C, Aguayo P, Smith CT, et al. Characterization of the bacterial biofilm communities present in reverse-osmosis water systems for haemodialysis. Microorganisms. 2020;8(9):1418.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  53. Khosravi AD, Hashemi Shahraki A, Hashemzadeh M, Sheini Mehrabzadeh R, Teimoori A. Prevalence of non-tuberculous mycobacteria in hospital waters of major cities of Khuzestan Province, Iran. Front Cell Infect Microbiol. 2016;6:42.

    Article  PubMed  PubMed Central  Google Scholar 

  54. Gomila M, Gascó J, Busquets A, Gil J, Bernabeu R, Buades JM, et al. Identification of culturable bacteria present in haemodialysis water and fluid. FEMS Microbiol Ecol. 2005;52(1):101–14.

    Article  CAS  PubMed  Google Scholar 

  55. Maltais JAB, Meyer KB, Foster MC. Comparison of techniques for culture of dialysis water and fluid. Hemodial Int. 2017;21(2):197–205.

    Article  PubMed  Google Scholar 

  56. Rekadwad BN, Khobragade CN. Morphotypes and pigment profiles of halophilic bacteria: practical data useful for novelty, taxonomic categorization and for describing novel species or new taxa. Data Brief. 2017;13:609–19.

    Article  PubMed  PubMed Central  Google Scholar 

  57. Arvanitidou M, Vayona A, Spanakis N, Tsakris A. Occurrence and antimicrobial resistance of Gram-negative bacteria isolated in haemodialysis water and dialysate of renal units: results of a Greek multicentre study. J Appl Microbiol. 2003;95(1):180–5. https://doi.org/10.1046/j.1365-2672.2003.01966.x.

    Article  CAS  PubMed  Google Scholar 

  58. Suman E, Varghese B, Joseph N, Nisha K, Kotian MS. The bacterial biofilms in dialysis water systems and the effect of the sub inhibitory concentrations of chlorine on them. J Clin Diagn Research: JCDR. 2013;7(5):849–52. https://doi.org/10.7860/jcdr/2013/5118.2956.

    Article  Google Scholar 

  59. Heidarieh P, Hashemi Shahraki A, Yaghoubfar R, Hajehasani A, Mirsaeidi M. Microbiological analysis of hemodialysis water in a developing country. ASAIO J. 2016;62(3):332–9.

    Article  PubMed  Google Scholar 

  60. Kinoshita C, Matsuda K, Kawai Y, Hagiwara T, Okada A. A case of Sphingomonas paucimobilis causing peritoneal dialysis-associated peritonitis and review of the literature. Ren Replace Therapy. 2021;7(1):64. https://doi.org/10.1186/s41100-021-00375-3.

    Article  Google Scholar 

  61. Wallner J, Frei R, Burkhalter F. A rare case of Peritoneal Dialysis-Associated Peritonitis with Sphingomonas koreensis. Perit Dial Int. 2016;36(2):224–5. https://doi.org/10.3747/pdi.2015.00065.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  62. Chaoui L, Chouati T, Zalegh I, Mhand RA, Mellouki F, Rhallabi N. Identification and assessment of antimicrobial resistance bacteria in a hemodialysis water treatment system. J Water Health. 2022;20(2):441–9.

    Article  PubMed  Google Scholar 

  63. Okano K, Furuta S, Ichise S, Miyata N. Whole-genome sequences of two manganese (II)-oxidizing bacteria, Bosea sp. strain BIWAKO-01 and alphaproteobacterium strain U9-1i. Genome Announcements. 2016;4(6):e01309–16.

    Article  PubMed  PubMed Central  Google Scholar 

  64. Szwetkowski KJ, Falkinham JO. 3rd. Methylobacterium spp. As Emerg Opportunistic Premise Plumbing Pathogens. 2020;9(2). https://doi.org/10.3390/pathogens9020149.

  65. Marcus DN, Pinto A, Anantharaman K, Ruberg SA, Kramer EL, Raskin L, et al. Diverse manganese (II)-oxidizing bacteria are prevalent in drinking water systems. Environ Microbiol Rep. 2017;9(2):120–8.

    Article  CAS  PubMed  Google Scholar 

  66. Palaneeswari MS, Rajan PM, Silambanan S. Jothimalar. Blood arsenic and cadmium concentrations in end-stage renal disease patients who were on maintenance haemodialysis. J Clin Diagn Research: JCDR. 2013;7(5):809–13. https://doi.org/10.7860/jcdr/2013/5351.2945.

    Article  Google Scholar 

  67. Kazi TG, Jalbani N, Kazi N, Jamali MK, Arain MB, Afridi HI, et al. Evaluation of toxic metals in blood and urine samples of chronic renal failure patients, before and after dialysis. Ren Fail. 2008;30(7):737–45. https://doi.org/10.1080/08860220802212999.

    Article  CAS  PubMed  Google Scholar 

  68. Dedania VS, Ghodasra DH, Zacks DN, POSTOPERATIVE ENDOPHTHALMITIS CAUSED BY BOSEAthiooxidans. Retinal Cases Brief Rep. 2017;11(4):329–31.

    Article  Google Scholar 

  69. Kovaleva J, Degener JE, van der Mei HC. Methylobacterium and its role in health care-associated infection. J Clin Microbiol. 2014;52(5):1317–21. https://doi.org/10.1128/jcm.03561-13.

    Article  PubMed  PubMed Central  Google Scholar 

  70. Wu H, Chen H, Wu W, Zheng P, Li Y. Methylobacterium infection-induced peritonitis in a patient with renal insufficiency: a case report and literature review. Int J Clin Pharmacol Ther. 2023.

  71. Roshdi Maleki M, Moaddab SR, Samadi kafil H. Hemodialysis waters as a source of potentially pathogenic mycobacteria (PPM). DESALINATION AND WATER TREATMENT; 2019.

  72. Adékambi T, Ben Salah S, Khlif M, Raoult D, Drancourt M. Survival of environmental mycobacteria in Acanthamoeba polyphaga. Appl Environ Microbiol. 2006;72(9):5974–81. https://doi.org/10.1128/aem.03075-05.

    Article  PubMed  PubMed Central  Google Scholar 

  73. Biglarnia F, Solhjoo K, Rezanezhad H, Taghipour A, Armand B. Isolation and identification of potentially pathogenic free-living amoeba in dialysis fluid samples of hydraulic systems in hemodialysis units. Trans R Soc Trop Med Hyg. 2022;116(5):454–61. https://doi.org/10.1093/trstmh/trab155.

    Article  PubMed  Google Scholar 

  74. Balczun C, Scheid PL. Free-living amoebae as hosts for and Vectors of Intracellular Microorganisms with Public Health significance. Viruses. 2017;9(4). https://doi.org/10.3390/v9040065.

  75. Tsao HF, Scheikl U, Herbold C, Indra A, Walochnik J, Horn M. The cooling tower water microbiota: Seasonal dynamics and co-occurrence of bacterial and protist phylotypes. Water Res. 2019;159:464–79. https://doi.org/10.1016/j.watres.2019.04.028.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  76. Jia S, Shi P, Hu Q, Li B, Zhang T, Zhang X-X. Bacterial Community Shift Drives Antibiotic Resistance Promotion during drinking Water Chlorination. Environ Sci Technol. 2015;49(20):12271–9. https://doi.org/10.1021/acs.est.5b03521.

    Article  CAS  PubMed  Google Scholar 

  77. Benedek T, Szentgyörgyi F, Gergócs V, Menashe O, Gonzalez PAF, Probst AJ, et al. Potential of Variovorax paradoxus isolate BFB1_13 for bioremediation of BTEX contaminated sites. AMB Express. 2021;11(1):126. https://doi.org/10.1186/s13568-021-01289-3.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  78. Czieborowski M, Hübenthal A, Poehlein A, Vogt I, Philipp B. Genetic and physiological analysis of biofilm formation on different plastic surfaces by Sphingomonas sp. strain S2M10 reveals an essential function of sphingan biosynthesis. Microbiology. 2020;166(10):918–35.

    Article  CAS  PubMed  Google Scholar 

  79. Zhao L, Liu Y-W, Li N, Fan X-Y, Li X. Response of bacterial regrowth, abundant and rare bacteria and potential pathogens to secondary chlorination in secondary water supply system. Sci Total Environ. 2020;719:137499.

    Article  CAS  PubMed  Google Scholar 

  80. Seneviratne G, Jayasinghearachchi HS. Mycelial colonization by bradyrhizobia and azorhizobia. J Biosci. 2003;28(2):243–7. https://doi.org/10.1007/bf02706224.

    Article  PubMed  Google Scholar 

  81. Fiebig A. Role of Caulobacter cell surface structures in colonization of the air-liquid interface. J Bacteriol. 2019;201(18). 10.1128/jb. 00064 – 19.

  82. Wang S, Qian K, Zhu Y, Yi X, Zhang G, Du G, et al. Reactivation and pilot-scale application of long-term storage denitrification biofilm based on flow cytometry. Water Res. 2019;148:368–77.

    Article  CAS  PubMed  Google Scholar 

  83. Zand E, Pfanner H, Domig KJ. Biofilm-Forming ability of Microbacterium lacticum and Staphylococcus capitis considering Physicochemical and Topographical Surface properties. 2021;10(3); https://doi.org/10.3390/foods10030611.

  84. Otto M. Staphylococcal biofilms. Curr Top Microbiol Immunol. 2008;322:207–28. https://doi.org/10.1007/978-3-540-75418-3_10.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  85. Vandecandelaere I, Matthijs N, Van Nieuwerburgh F, Deforce D, Vosters P, De Bus L, et al. Assessment of microbial diversity in biofilms recovered from endotracheal tubes using culture dependent and independent approaches. PLoS ONE. 2012;7(6):e38401.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  86. Esteban J, García-Coca M. Mycobacterium Biofilms. Front Microbiol. 2017;8:2651. https://doi.org/10.3389/fmicb.2017.02651.

    Article  PubMed  Google Scholar 

  87. Stoodley P, Sauer K, Davies DG, Costerton JW. Biofilms as complex differentiated communities. Annu Rev Microbiol. 2002;56(1):187–209.

    Article  CAS  PubMed  Google Scholar 

  88. Saarela M, Alakomi H-L, Suihko M-L, Maunuksela L, Raaska L, Mattila-Sandholm T. Heterotrophic microorganisms in air and biofilm samples from roman catacombs, with special emphasis on actinobacteria and fungi. Int Biodeterior Biodegrad. 2004;54(1):27–37.

    Article  Google Scholar 

  89. Yang J, Hu Y, Zhang Y, Zhou S, Meng D, Xia S, et al. Deciphering the diversity and assemblage mechanisms of nontuberculous mycobacteria community in four drinking water distribution systems with different disinfectants. Sci Total Environ. 2024;907:168176.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This work was approved in Infectious and Tropical Diseases Research Center, and was financially supported by Grants (No: OG-95105) from Research Affairs, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.

The funding bodies did not play any role in the design of the study and collection, analysis, and interpretation of data, neither in writing the manuscript.

Author information

Authors and Affiliations

Authors

Contributions

S.G and S.K conceived the study, drafted the experimental protocol and manuscript. S.M.A analyzed and interpreted the patient’s data. S.G, S.K performed the experiments and analyzed the data. S.G and S.K contributed to writing, reviewing, and revising the paper. All authors interpreted the data and critically reviewed drafts of the manuscript. All authors edited and approved the final manuscript.

Corresponding author

Correspondence to Soheila Khaghani.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ghafari, S., Alavi, S.M. & Khaghani, S. Potentially pathogenic culturable bacteria in hemodialysis waters. BMC Microbiol 24, 276 (2024). https://doi.org/10.1186/s12866-024-03430-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12866-024-03430-1

Keywords