Skip to main content

Table 5 The consensus of the results of TaqMan One-Step RT-qPCR, One-Step LAMP, and LICT in the diagnosis of SARS-CoV-2 among patients

From: Rapid, sensitive, and specific detection of SARS-CoV-2 in nasopharyngeal swab samples of suspected patients using a novel one-step loop-mediated isothermal amplification (one-step LAMP) technique

 

LICT

Total

 

Negative

n (%)

Positive

n (%)

One-Step LAMP

Negative

123 (48.4)

4 (1.6)

127 (50.0)

P < 0.001

Positive

103 (40.6)

24 (9.4)

127 (50.0)

Kappa = 24%

One-Step RT-qPCR

Negative

123 (48.4)

0 (0.0)

123 (48.4)

P < 0.001

Positive

103 (40.6)

28 (11.0)

131 (51.6)

Kappa = 32%