Skip to main content

Table 1 Log reductions of E. coli O157:H7 in 72, 48, 36, 24, and 18 °Brix apple juice subjected to ohmic heating at 30 and 60 V/cm

From: Investigation of optimum ohmic heating conditions for inactivation of Escherichia coli O157:H7, Salmonella enterica serovar Typhimurium, and Listeria monocytogenes in apple juice

Voltage

 

Log reduction [log10 (N0/N)]a by treatment time (s)

gradient

°Brix

0

 

10

 

20

 

30

 

40

 

50

 

60

 

30 V/cm

72

0.00 ± 0.00

A

0.44 ± 0.22

B

0.42 ± 0.05

B

0.53 ± 0.16

B

0.56 ± 0.32

B

0.71 ± 0.22

BC

0.95 ± 0.03

C

48

0.00 ± 0.00

A

0.26 ± 0.07

A

0.34 ± 0.02

A

0.41 ± 0.05

A

0.89 ± 0.22

B

1.38 ± 0.22

C

2.59 ± 0.63

D

36

0.00 ± 0.00

A

0.28 ± 0.14

A

0.34 ± 0.04

A

0.91 ± 0.37

B

1.40 ± 0.30

C

3.33 ± 0.31

D

6.78 ± 0.11

E

24

0.00 ± 0.00

A

0.24 ± 0.08

AB

0.22 ± 0.13

AB

0.71 ± 0.48

BC

1.26 ± 0.46

C

2.97 ± 0.47

D

5.21 ± 0.36

E

18

0.00 ± 0.00

A

0.09 ± 0.08

A

0.17 ± 0.30

AB

0.17 ± 0.06

AB

0.67 ± 0.31

B

1.34 ± 0.50

C

2.71 ± 0.29

D

60 V/cm

72

0.00 ± 0.00

A

0.38 ± 0.22

AB

0.67 ± 0.22

B

0.62 ± 0.06

B

0.55 ± 0.29

AB

0.73 ± 0.32

B

0.73 ± 0.60

B

48

0.00 ± 0.00

A

0.42 ± 0.13

B

6.33 ± 0.13

C

ND

 

ND

 

ND

 

ND

 

36

0.00 ± 0.00

A

0.82 ± 0.17

B

6.58 ± 0.22

C

ND

 

ND

 

ND

 

ND

 

24

0.00 ± 0.00

A

0.74 ± 0.58

B

6.88 ± 0.06

C

ND

 

ND

 

ND

 

ND

 

18

0.00 ± 0.00

A

0.50 ± 0.41

B

6.93 ± 0.11

C

ND

 

ND

 

ND

 

ND

 
  1. aThe values are means ± standard deviations from three replications. Values in the same row followed by the same letter are not significantly different (P > 0.05). ND not detected.