Skip to main content

Table 4 Comparison between the dual-function-ELISA and virus neutralization in antibody detection with pooled mice sera after a single H7 immunization

From: Development of dual-function ELISA for effective antigen and antibody detection against H7 avian influenza virus

Virus immunized

Inhibition in dual ELISA at 1:20 dilution

Dual ELISA titer at 30% cut-off

Virus neutralization titer

H7N3/A/Canada/rv504/04

91.47%

500

160

H7N6/A/quail/Aichi/4/09

61.64%

100

40

H7N7/A/duck/Hokkaido/1/10

92.84%

500

160

H7N7/A/Netherlands/219/03

94.68%

1000

320

Pre-immunization sera

4.14%

<20

<20